Pharma & clinical. Gas you can validate.

From QC release testing to LC-MS/MS bioanalysis, cell culture, hydrogenation and deuterated compounds: the nitrogen, hydrogen, zero air, oxygen and deuterium of a pharmaceutical lab, made on site.

6applications
7Leman product lines
404instruments listed

What this industry needs

Formulation QC, dissolution, LC-MS/MS bioanalysis and clinical panels all run under strict method validation.

A documented, constant on-site gas supply is easier to validate against than a cylinder batch that changes with every delivery.

H2D2N2AirO2
99 %nitrogen grade most LC-MS/MS bioanalysis is specified around
1 kg → 1,000 Lof D₂ from heavy water in a DIHYDRO generator
0cylinders to move through classified rooms

How it works

From the sample or the process to the result, and the gas used at each step.

Discovery

LC-MS, NMR and SFC identify and purify new molecules; deuterated analogues are made with D₂.

D2N2Air
Development

Methods are validated for assay, impurities, residual solvents and elemental impurities.

H2N2Air
Release testing

Every batch is tested against its specification before it can leave the site.

H2N2AirO2
Water and cleaning

TOC proves the purity of water for injections and the cleaning of shared equipment.

AirO2

In depth

01N2

Validating the gas once

A validated chromatographic method assumes the gas does not change. Cylinders do change, from one batch to the next. A generator delivers the same purity day after day, from the same documented source, which makes the gas supply part of the validated system rather than a variable.

02D2

Deuterium for better drugs

Replacing hydrogen with deuterium at the right place in a molecule can slow its metabolism, and deuterated compounds are also the internal standards of LC-MS bioanalysis. Both are made with deuterium gas. A DIHYDRO generator electrolyses heavy water into D₂ on site, from lab-scale reactions to bottle filling.

On the bench

Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.

ApplicationEquipmentGas it needsLeman generator
LC-MS/MS bioanalysisTriple-quadrupole LC-MSN₂ nebuliser, desolvation and curtain gasSOLO LCMS
ELSD / CAD, dissolution and HPLCHPLC with ELSD or CADN₂ at constant pressureNITRO ELSD
Residual solvents, GC-FID / GC-MSHeadspace GC-FID and GC-MSH₂ carrier, zero airHYDRO50 LAERO50 LGCSTATION NEO
CHNS elemental, formulation QCCHNS / O elemental analysersO₂ combustionOXY50 L
Clinical LC-MS panelsClinical triple-quadrupole LC-MSN₂ + zero air togetherDUO LCMS
Deuteration and labelled standardsCatalytic H/D exchange, D₂ reduction, bottle fillingD₂ gas, chemical purity > 99.9995 %DIHYDRO50 LS2DIHYDRO50 L

Instruments we know

From our compatibility lists: each family with its gases and the Leman generators that run it.

Chromatography and impurity profiling · USP <621>

N2Air

Leman generatorsSOLO LCMS · DUO LCMS · NITRO50 L · NITRO ELSD

112 instruments in our compatibility lists

Residual solvents · USP <467> · ICH Q3C

H2N2Air

Leman generatorsGCSTATION NEO · NANO TOWER · NANO N2 · HYDRO50 L

77 instruments in our compatibility lists

Elemental impurities · ICH Q3D · USP <232>/<233>

H2N2AirO2

Leman generatorsNITRO ICP · HYDRO50 L · OXY50 L · NANO COMP

44 instruments in our compatibility lists
680°C

Water and cleaning validation · USP <643>

N2AirO2

Leman generatorsAERO TOC L · OXY50 L · NITRO50 L · NANO COMP

35 instruments in our compatibility lists

Identity and solid state · USP <197> · USP <891>

N2AirO2

Leman generatorsNANO N2 · AERO FTIR L · NANO ZA · OXY50 L

62 instruments in our compatibility lists

Structure elucidation · NMR

N2Air

Leman generatorsAERO50 LS · AERO50 LS2 · NITRO30 LS2 · NITRO50 LS

14 instruments in our compatibility lists
CO₂

Chiral separation and purification

N2Air

Leman generatorsNITRO ELSD · NITRO20 LS2 · NANO COMP · SOLO LCMS

29 instruments in our compatibility lists
1%

Biologics and cell culture

N2Air

Leman generatorsNITRO50 LS · NANO COMP · NANO N2 · NITRO50 L

23 instruments in our compatibility lists

Process chemistry and hydrogenation

H2D2

Leman generatorsHYDRO50 L · DIHYDRO50 L

8 instruments in our compatibility lists
Lab Gas PlannerA typical pharmaceutical lab, sized in one click
  • 3 × LC-MS · Triple quadrupole
  • 2 × GC · Laboratory GC
  • 1 × TD & headspace · Headspace
  • 1 × ICP · ICP-MS
  • 1 × TOC · Combustion TOC
  • 1 × FTIR · Laboratory FTIR
  • 1 × Thermal · DSC
  • 1 × NMR · Solution NMR
  • 1 × ELSD · HPLC ELSD
Open in the planner

Questions we hear

Straight answers to what labs ask us first.

We can't change a gas source without a full re-validation.

A documented, constant-purity source is validated once; a cylinder changes with every delivery. Your validated method still sets the specification — our engineers document the generator against it.

Does your method still match the gas it was validated with?

With a generator the purity does not drift from one delivery to the next, which is exactly what a validated method needs.

Can you make deuterium for our deuteration chemistry?

Yes: DIHYDRO generators electrolyse heavy water into D₂ gas on site. One DIHYDRO50 LS2-40 makes up to 12 kg of D₂ a day; smaller L and LS models cover lab-scale reactions.

Your instrument is not listed?Send us the maker, model and detectors: we tell you which generator fits.Ask our engineers

Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.