Pharma & clinical. Gas you can validate.
From QC release testing to LC-MS/MS bioanalysis, cell culture, hydrogenation and deuterated compounds: the nitrogen, hydrogen, zero air, oxygen and deuterium of a pharmaceutical lab, made on site.
NITROWhat this industry needs
Formulation QC, dissolution, LC-MS/MS bioanalysis and clinical panels all run under strict method validation.
A documented, constant on-site gas supply is easier to validate against than a cylinder batch that changes with every delivery.
How it works
From the sample or the process to the result, and the gas used at each step.
LC-MS, NMR and SFC identify and purify new molecules; deuterated analogues are made with D₂.
Methods are validated for assay, impurities, residual solvents and elemental impurities.
Every batch is tested against its specification before it can leave the site.
TOC proves the purity of water for injections and the cleaning of shared equipment.
Where Leman fits
The Leman product lines this industry uses, and what each one does.
Lead product lineNITRONitrogen, 99 % to 99.99995 %N2LC-MS/MS, the highest-volume instrument in pharma, ELSD and CAD for HPLC, and the same purity every day a validated method depends on.
SOLO / DUO / TRIO LCMSNitrogen and zero air for LC-MSN2AirSOLO LCMS for nitrogen only, DUO LCMS when the source also needs zero air, TRIO when it needs two zero-air streams and nitrogen.
AEROZero air, AERO50 to AERO70AirZero air for FID and combustion methods run alongside LC-MS in the same lab.
HYDROHydrogen, three PEM purity gradesH2GC and GC-MS carrier gas for residual solvents, and hydrogen for flow and batch hydrogenation.
OXYOxygen 99.999 %O2CHNS elemental analysis for formulation QC, and oxygen for OIT tests in thermal analysis.
DIHYDRODeuterium from heavy waterD2Deuterium gas from heavy water for deuterated APIs and labelled reference standards: chemical purity above 99.9995 %, isotopic purity set by the heavy water you supply.
GCSTATION NEO / NANO TOWERH₂ + N₂ + zero air for GCH2N2AirThe complete GC gas supply for a QC lab running several techniques in parallel.
In depth
Validating the gas once
A validated chromatographic method assumes the gas does not change. Cylinders do change, from one batch to the next. A generator delivers the same purity day after day, from the same documented source, which makes the gas supply part of the validated system rather than a variable.
Deuterium for better drugs
Replacing hydrogen with deuterium at the right place in a molecule can slow its metabolism, and deuterated compounds are also the internal standards of LC-MS bioanalysis. Both are made with deuterium gas. A DIHYDRO generator electrolyses heavy water into D₂ on site, from lab-scale reactions to bottle filling.
On the bench
Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.
| Application | Equipment | Gas it needs | Leman generator |
|---|---|---|---|
| LC-MS/MS bioanalysis | Triple-quadrupole LC-MS | N₂ nebuliser, desolvation and curtain gas | SOLO LCMS |
| ELSD / CAD, dissolution and HPLC | HPLC with ELSD or CAD | N₂ at constant pressure | NITRO ELSD |
| Residual solvents, GC-FID / GC-MS | Headspace GC-FID and GC-MS | H₂ carrier, zero air | HYDRO50 LAERO50 LGCSTATION NEO |
| CHNS elemental, formulation QC | CHNS / O elemental analysers | O₂ combustion | OXY50 L |
| Clinical LC-MS panels | Clinical triple-quadrupole LC-MS | N₂ + zero air together | DUO LCMS |
| Deuteration and labelled standards | Catalytic H/D exchange, D₂ reduction, bottle filling | D₂ gas, chemical purity > 99.9995 % | DIHYDRO50 LS2DIHYDRO50 L |
Instruments we know
From our compatibility lists: each family with its gases and the Leman generators that run it.
Chromatography and impurity profiling · USP <621>
Leman generatorsSOLO LCMS · DUO LCMS · NITRO50 L · NITRO ELSD
112 instruments in our compatibility listsResidual solvents · USP <467> · ICH Q3C
Leman generatorsGCSTATION NEO · NANO TOWER · NANO N2 · HYDRO50 L
77 instruments in our compatibility listsElemental impurities · ICH Q3D · USP <232>/<233>
Water and cleaning validation · USP <643>
Leman generatorsAERO TOC L · OXY50 L · NITRO50 L · NANO COMP
35 instruments in our compatibility listsIdentity and solid state · USP <197> · USP <891>
Leman generatorsNANO N2 · AERO FTIR L · NANO ZA · OXY50 L
62 instruments in our compatibility listsStructure elucidation · NMR
Leman generatorsAERO50 LS · AERO50 LS2 · NITRO30 LS2 · NITRO50 LS
14 instruments in our compatibility listsChiral separation and purification
Leman generatorsNITRO ELSD · NITRO20 LS2 · NANO COMP · SOLO LCMS
29 instruments in our compatibility listsBiologics and cell culture
Leman generatorsNITRO50 LS · NANO COMP · NANO N2 · NITRO50 L
23 instruments in our compatibility listsProcess chemistry and hydrogenation
Leman generatorsHYDRO50 L · DIHYDRO50 L
8 instruments in our compatibility lists- 3 × LC-MS · Triple quadrupole
- 2 × GC · Laboratory GC
- 1 × TD & headspace · Headspace
- 1 × ICP · ICP-MS
- 1 × TOC · Combustion TOC
- 1 × FTIR · Laboratory FTIR
- 1 × Thermal · DSC
- 1 × NMR · Solution NMR
- 1 × ELSD · HPLC ELSD
Questions we hear
Straight answers to what labs ask us first.
We can't change a gas source without a full re-validation.
A documented, constant-purity source is validated once; a cylinder changes with every delivery. Your validated method still sets the specification — our engineers document the generator against it.
Does your method still match the gas it was validated with?
With a generator the purity does not drift from one delivery to the next, which is exactly what a validated method needs.
Can you make deuterium for our deuteration chemistry?
Yes: DIHYDRO generators electrolyse heavy water into D₂ gas on site. One DIHYDRO50 LS2-40 makes up to 12 kg of D₂ a day; smaller L and LS models cover lab-scale reactions.
Other industries
Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.