Applications · By industry
Petrochemical & refining. Every gas on one bench.
Crude assay, fuel-blend QC, sulfur compliance and process-gas analysis all run on GC, GC-MS and combustion analysers — banks of instruments drawing carrier, fuel and make-up gas around the clock. Leman makes each of those gases on site.
HYDROWhat this industry needs
Refinery and petrochemical labs run GC and GC-MS at a scale few other industries match, often several instruments in parallel, each drawing carrier, flame and make-up gas continuously.
Sulfur in fuels is a repeat regulatory test for as long as the plant runs, and combustion analysers are among the heaviest oxygen users of any lab.
How it works
From the sample or the process to the result, and the gas used at each step.
Simulated distillation and crude assay by GC tell the refinery what it bought and how to run the units.
Process and online GCs watch the streams around the clock, from refinery gas to aromatics.
Detailed hydrocarbon analysis, oxygenates and PIONA check every gasoline and diesel blend.
Sulfur by combustion or chemiluminescence proves compliance before the product ships.
Where Leman fits
The Leman product lines this industry uses, and what each one does.
Lead product lineHYDROHydrogen, three PEM purity gradesH2The carrier-gas story lands hardest here: refinery labs were among the first to move off helium. HYDRO65 and HYDRO70 for carrier gas, HYDRO50 for FID flames.
AEROZero air, AERO50 to AERO70AirZero air for the FID and FPD flame of every GC bench, plus the AERO70 ppb grade for calibration and trace work.
OXYOxygen 99.999 %O2Sulfur-in-oil and sulfur chemiluminescence QC, and combustion elemental analysis.
NITRONitrogen, 99 % to 99.99995 %N299.9995 % carrier and make-up gas, and nitrogen for purge and blanketing in the lab.
GCSTATION NEO / NANO TOWERH₂ + N₂ + zero air for GCH2N2AirThe complete three-gas answer for a bench running FID, GC-MS and ECD side by side.
19" RACK SERIESH₂, N₂ and zero air in a 19" rackH2N2AirH₂ and zero air in 19" racks for process analysers and online GC shelters.
In depth
Hydrogen instead of helium
Helium has become expensive and its supply uncertain. Hydrogen is the faster carrier gas in GC: separations keep their resolution at higher velocities, so runs often get shorter. Refinery labs were among the first to move at scale, and a HYDRO generator makes that carrier gas from water, at the instrument, with only a few millilitres stored inside.
Why oxygen matters for sulfur
Sulfur chemiluminescence detectors burn the column effluent in a hydrogen–oxygen flame and combustion analysers burn the whole sample in oxygen. Both measure sulfur at low levels batch after batch, for as long as the refinery runs. An OXY generator delivers 99.999 % oxygen on demand instead of a rack of cylinders that empties every week.
On the bench
Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.
| Application | Equipment | Gas it needs | Leman generator |
|---|---|---|---|
| GC-FID / FPD, crude and process analysis | Laboratory GC with FID and FPD | H₂ carrier and flame fuel, zero air | HYDRO50 LAERO50 LGCSTATION NEO |
| Sulfur chemiluminescence (SCD) | GC with sulfur chemiluminescence detector | H₂ fuel, O₂ combustion | HYDRO50 LOXY50 L |
| Sulfur in oil | Combustion-route sulfur analysers | O₂ combustion, every batch | OXY50 L |
| GC-MS, trace hydrocarbons | Single-quadrupole GC-MS | H₂ carrier, ultra-pure make-up | HYDRO65 LNITRO65 L |
| CHNS / elemental combustion | Large combustion analysers | O₂ at up to 7 L/min | OXY50 L-7 |
Instruments we know
From our compatibility lists: each family with its gases and the Leman generators that run it.
GC and GC-MS
Leman generatorsGCSTATION NEO · NANO TOWER · HYDRO70 L · NANO N2
112 instruments in our compatibility listsProcess, natural-gas and online GC
Leman generatorsFIDSTATION50 RC · HYDRO50 L · HYDRO50 R
57 instruments in our compatibility listsSulfur, carbon and elemental analysis
Gas analysers
- 4 × GC · Laboratory GC
- 1 × GC · GC-MS
- 1 × Elemental · TN / TS / TX analysers
- 1 × Elemental · Carbon / sulfur
Questions we hear
Straight answers to what labs ask us first.
We already have a compressed-air line and a cylinder contract that works.
Keep the compressed-air line: it is exactly what HYDRO and AERO generators run on. The change replaces the one line item that is both expensive and unreliable — helium and hydrogen cylinders.
Will hydrogen carrier gas change our methods?
Many GC methods can move from helium to hydrogen with faster runs; your validated method decides. Our engineers help you size the HYDRO for each instrument.
Other industries
Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.