Oxygen generators

Up to 99.999 % oxygen, 0.25 to 7 L/min — the first on-site oxygen generator built for the analytical laboratory.

Until OXY, oxygen was the one laboratory gas with no generator alternative. OXY produces it on demand from compressed air with a patented smart PSA process, so combustion analysers and SCD detectors no longer depend on cylinder deliveries.

Two grades on the same platform: OXY50 for analytical purity, OXY20 for everyday utility oxygen. OXY is formally recommended by Shimadzu Asia Pacific for GC-SCD systems.

99.999 %

O₂ with OXY50

2

purity grades

0.25–7

L/min

5

flow models per grade

How it works

Oxygen from air, in four steps

The generator keeps the oxygen in your compressed air and removes everything else.

01

Compressed air

Oil-free, dry compressed air from your house line or a compressor.

02

Filtration

Particles and moisture are removed before separation.

03

Patented smart PSA

Several molecular beds hold back nitrogen, argon and traces — leaving pure oxygen.

04

To your instrument

O₂ is buffered, filtered to 0.01 µm and regulated electronically from 0.5 to 5 bar.

Step 1

Choose your grade

Same platform, same casing — the grade sets how far the oxygen is purified.

Analytical

OXY50

99.999 %

  • N₂ < 10 ppm
  • THC / CH₄ < 1 ppm
  • Dew point –50 °C

GC-SCD, sulphur / nitrogen / halide combustion analysis.

Entry level

OXY20

≈ 99 %

  • Dew point –30 °C
  • 0.5 – 5 bar
  • Same chassis as OXY50

NOx efficiency testers, burners, general oxygen supply.

Step 2

Two casings, by flow

Up to 1 L/min in the compact floor casing, 4 and 7 L/min in the extended-capacity casing.

oxy l oxygen generator

Compact casing

L-250 · L-500 · L-1

0.25 – 1 L/min

40.5 × 32.5 × 69 cm — for one or two analysers.

OXY L-4 and L-7 extended-capacity oxygen generator with O2 touchscreen

Extended capacity

L-4 · L-7

4 – 7 L/min

70 × 48 × 69 cm, on castors — for higher-flow combustion systems.

Where OXY generators work

  • GC-SCD ozone generators (Shimadzu, Agilent)
  • Sulphur, nitrogen and halide combustion analysis (LECO, PAC)
  • NOx efficiency testers
  • Food, water and petrochemical testing
  • Pharmaceutical elemental analysis
  • Organic and inorganic spectroscopy

Common to every model

  • Patented, field-proven smart PSA
  • Runs on oil-free, dry compressed air
  • Ethernet, USB and RS485 control
  • Automatic switching 90 – 260 VAC
  • No high-pressure oxygen stored in the lab
  • No cylinders, no deliveries, no rental