Applications · By industry
Forensics & toxicology. Start without cylinders.
Forensic toxicology, cannabis potency and pesticide-residue testing run on GC-MS and LC-MS. A newly built lab can specify its gases from a blank sheet — with a generator instead of a cylinder contract.
NITROWhat this industry needs
Forensic toxicology, cannabis potency and pesticide residues, and clinical toxicology panels all run on GC-MS and LC-MS.
Many of these labs are new, built in the last decade, with no legacy cylinder infrastructure to replace.
How it works
From the sample or the process to the result, and the gas used at each step.
Blood, urine, plant material or seized products enter a chain of custody.
Headspace GC for alcohol and volatiles, LC-MS/MS screening for drugs and metabolites.
GC-MS and LC-MS/MS confirm and quantify every positive result.
Results go to court or to the regulator — the run cannot be repeated if the sample is used up.
Where Leman fits
The Leman product lines this industry uses, and what each one does.
Lead product lineNITRONitrogen, 99 % to 99.99995 %N2The primary fit: LC-MS/MS for potency and pesticide panels, GC-MS for forensic toxicology, at the grade each method specifies.
SOLO / DUO / TRIO LCMSNitrogen and zero air for LC-MSN2AirSOLO LCMS for nitrogen, DUO LCMS when a low detection limit asks for nitrogen and zero air of MS grade.
GCSTATION NEO / NANO TOWERH₂ + N₂ + zero air for GCH2N2AirThe complete gas answer for a lab specifying its GC infrastructure for the first time.
HYDROHydrogen, three PEM purity gradesH2Hydrogen carrier gas for GC-MS, and fuel for headspace blood-alcohol FIDs.
In depth
A lab built from a blank sheet
New testing labs choose their gas supply once, at the start. A GCSTATION NEO gives the GC bench hydrogen, nitrogen and zero air from one unit; each LC-MS gets its own SOLO or DUO LCMS. There are no cylinder racks to plan, no deliveries to schedule, and nothing to secure in the corridor.
Never lose a sample to an empty cylinder
Forensic samples are often limited. A sequence that stops halfway because a cylinder emptied can consume material that cannot be replaced. Generators run as long as the instrument runs.
On the bench
Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.
| Application | Equipment | Gas it needs | Leman generator |
|---|---|---|---|
| Cannabis potency LC-MS/MS | Triple-quadrupole LC-MS | N₂ nebuliser and curtain gas | SOLO LCMS |
| Pesticide residue screening | Triple-quadrupole and hybrid LC-MS | N₂ of demanding-MS grade | DUO LCMS |
| Forensic toxicology GC-MS | GC-MS | H₂ carrier | HYDRO50 LGCSTATION NEO |
| Blood alcohol, headspace GC-FID | Headspace GC with dual FID | H₂, zero air, N₂ | GCSTATION NEO |
| New lab, full GC gas supply | Any GC / GC-MS platform | H₂, N₂ and zero air in one order | GCSTATION NEO |
Instruments we know
From our compatibility lists: each family with its gases and the Leman generators that run it.
LC-MS toxicology and residues
Leman generatorsSOLO LCMS · DUO LCMS · NITRO50 L · NITRO30 LS2
85 instruments in our compatibility listsGC-MS and GC
Leman generatorsGCSTATION NEO · NANO TOWER · HYDRO70 L · NANO N2
112 instruments in our compatibility listsHeadspace and thermal desorption
Leman generatorsNANO N2
12 instruments in our compatibility lists- 2 × LC-MS · Triple quadrupole
- 2 × GC · GC-MS
- 1 × GC · Laboratory GC
- 1 × TD & headspace · Headspace
Questions we hear
Straight answers to what labs ask us first.
We have no track record with Leman.
Start from the numbers: no cylinders, no changeover, constant purity. The gas saving calculator shows the payback for your own instruments.
Which generator for a lab built from scratch?
One GCSTATION NEO covers the GC bench; SOLO or DUO LCMS covers each LC-MS. The Lab Gas Planner sizes the whole lab.
Other industries
Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.