Search

Applications · By industry

Battery manufacturing. Dry nitrogen at the point of use.

Electrode coating, cell assembly and formation run in dry rooms and glove boxes held at −40 to −70 °C dew point. NITRO generators make that nitrogen where it is used.

4applications
2Leman product lines
43instruments listed

What this industry needs

Lithium-ion cell manufacturing runs inside dry rooms and glove boxes held at very low dew points: trace moisture degrades cell chemistry and shortens service life.

Gigafactory capacity is growing faster than almost any other industry.

N2Air
−40 to −70 °Cdew point range of battery dry rooms and glove boxes
< 1 % RHaccepted humidity ceiling for lithium battery production
−70 °CNITRO65 dew point

How it works

From the sample or the process to the result, and the gas used at each step.

Electrode coating

Coated electrodes are dried and handled in dry rooms at very low dew point.

N2
Cell assembly

Stacking, winding and electrolyte filling happen in dry rooms or glove boxes.

N2
Formation

Cells are charged for the first time under controlled conditions.

Lab and R&D

Materials and cells are characterised in glove boxes and analytical labs.

N2Air

In depth

01N2

Why the dew point

Lithium salts in the electrolyte react with water, forming acids that degrade the cell. That is why battery dry rooms run at −40 °C dew point or below and glove boxes at ppm moisture. NITRO50 and NITRO65 deliver nitrogen at −50 to −70 °C dew point.

02N2

Point of use

Nitrogen piped a long way from a central plant can pick up moisture. A generator at the glove box or the dry-room skid delivers dry gas where it is used — and a SLIM unit can be built directly into the equipment.

On the bench

Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.

ApplicationEquipmentGas it needsLeman generator
Dry-room atmosphere controlDry rooms and dehumidification systemsN₂ at −40 to −70 °C dew pointNITRO50 LSNITRO65 LS
Glove boxes for cell R&DInert-gas glove boxesUltra-high-purity N₂, O₂ and H₂O at ppmNITRO65 LNITRO65 LS
Electrolyte handling and storageDesiccator cabinetsInert N₂, moisture exclusionNITRO50 L
Built into a dry-room skid (OEM)Dry-room and dehumidification integratorsA 45 mm panel specified onceWSN2

Instruments we know

From our compatibility lists: each family with its gases and the Leman generators that run it.

Glove boxes

N2

Leman generatorsNITRO50 LS

4 instruments in our compatibility lists

Battery materials analysis

N2AirO2

Leman generatorsNANO N2 · NANO ZA · NITRO ICP · NANO COMP

39 instruments in our compatibility lists

Questions we hear

Straight answers to what labs ask us first.

Our dry room already runs on bulk nitrogen from a central plant.

Nitrogen piped a long way can pick up moisture. NITRO generates at the point of use, at the dew point the dry room is specified for.

Your instrument is not listed?Send us the maker, model and detectors: we tell you which generator fits.Ask our engineers

Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.