Applications · By industry
Battery manufacturing. Dry nitrogen at the point of use.
Electrode coating, cell assembly and formation run in dry rooms and glove boxes held at −40 to −70 °C dew point. NITRO generators make that nitrogen where it is used.
NITROWhat this industry needs
Lithium-ion cell manufacturing runs inside dry rooms and glove boxes held at very low dew points: trace moisture degrades cell chemistry and shortens service life.
Gigafactory capacity is growing faster than almost any other industry.
How it works
From the sample or the process to the result, and the gas used at each step.
Coated electrodes are dried and handled in dry rooms at very low dew point.
Stacking, winding and electrolyte filling happen in dry rooms or glove boxes.
Cells are charged for the first time under controlled conditions.
Materials and cells are characterised in glove boxes and analytical labs.
Where Leman fits
The Leman product lines this industry uses, and what each one does.
Lead product lineNITRONitrogen, 99 % to 99.99995 %N2NITRO50 and NITRO65 dew points of −50 to −70 °C sit inside the range dry rooms and glove boxes are built to hold, for coating, assembly and electrolyte handling.
SLIM45 mm wall and OEM generatorsN2AirBuilt into a glove box or a dry-room monitoring skid instead of piped from a central plant.
In depth
Why the dew point
Lithium salts in the electrolyte react with water, forming acids that degrade the cell. That is why battery dry rooms run at −40 °C dew point or below and glove boxes at ppm moisture. NITRO50 and NITRO65 deliver nitrogen at −50 to −70 °C dew point.
Point of use
Nitrogen piped a long way from a central plant can pick up moisture. A generator at the glove box or the dry-room skid delivers dry gas where it is used — and a SLIM unit can be built directly into the equipment.
On the bench
Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.
| Application | Equipment | Gas it needs | Leman generator |
|---|---|---|---|
| Dry-room atmosphere control | Dry rooms and dehumidification systems | N₂ at −40 to −70 °C dew point | NITRO50 LSNITRO65 LS |
| Glove boxes for cell R&D | Inert-gas glove boxes | Ultra-high-purity N₂, O₂ and H₂O at ppm | NITRO65 LNITRO65 LS |
| Electrolyte handling and storage | Desiccator cabinets | Inert N₂, moisture exclusion | NITRO50 L |
| Built into a dry-room skid (OEM) | Dry-room and dehumidification integrators | A 45 mm panel specified once | WSN2 |
Instruments we know
From our compatibility lists: each family with its gases and the Leman generators that run it.
Battery materials analysis
Questions we hear
Straight answers to what labs ask us first.
Our dry room already runs on bulk nitrogen from a central plant.
Nitrogen piped a long way can pick up moisture. NITRO generates at the point of use, at the dew point the dry room is specified for.
Other industries
Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.