Gas generator line · LC-MS
LC-MS gas generators
Nitrogen and zero air for SCIEX, Shimadzu, Bruker, PerkinElmer, Thermo Fisher, Agilent and Waters — from 20 to 90 L/min.
SOLO, DUO and TRIO make, next to your mass spectrometer, exactly the gases it draws — from the compressed air of your laboratory. No cylinders, no dewars, nothing to replace inside.
NitrogenSOLO LCMS
20 · 35 · 60 NL/minFor nitrogen-only LC-MS: Thermo Fisher, Agilent, Waters, Shimadzu LCMS-2050
Nitrogen + zero airDUO LCMS
30/30 · 35/50 · 20/70 NL/minOne version per brand: Shimadzu, Bruker EVOQ, PerkinElmer QSight
The LC-MS family · nitrogen and zero air
Gas matched to your exact LC-MS — not to a catalogue
LC-MS is the thirstiest instrument in the laboratory: 20 to 90 L/min of nitrogen and zero air, day and night. Each manufacturer asks for a different combination of gases, flows and pressures — so we built one generator for each of them.
SOLO for nitrogen-only platforms, DUO for the dual-gas systems of Shimadzu, Bruker and PerkinElmer, TRIO for the three-gas design of SCIEX. Each one delivers exactly what your instrument draws, from the compressed air you already have.
No compressor and no consumables inside. PSA over carbon molecular sieve: nothing to replace in the generator, the same purity and pressure every day.
Find the generator for your instrument
| Thermo Fisher | TSQ series | SOLO LCMS |
| Agilent | 6400 series | SOLO LCMS |
| Waters | Xevo TQ series | SOLO LCMS |
| Shimadzu | LCMS-2050 | SOLO LCMS |
| Shimadzu | LCMS-8045 · 8050 · 8060 · 9030 | DUO LCMS-30/30 |
| Bruker | EVOQ | DUO LCMS-35/50 |
| PerkinElmer | QSight (single or dual source) | DUO LCMS-20/70 |
| SCIEX | API 3200 to QTRAP 5500 | TRIO LCMS |
| SCIEX | Nitrogen-only configurations | SOLO LCMS |
| Cylinders and liquid-nitrogen dewars | Leman LC-MS generator | |
|---|---|---|
| Supply | About one B50 cylinder every working day for a single busy instrument | Continuous, from your compressed-air network |
| Consistency | Purity and pressure vary from cylinder to cylinder | The same purity and pressure every day |
| Gases | One cylinder bank per gas, one regulator per line | Two or three gases from one unit, each at its own pressure |
| Losses | Dewars evaporate even at night and over weekends | Gas made only as the instrument draws it |
| Handling | Heavy cylinders, cryogenic liquid, changeovers mid-sequence | None — runs 24/7 next to the instrument |
Why a Leman LC-MS generator
Built around the instrument, not the other way round
Sized to each brand
30/30 for Shimadzu, 35/50 for Bruker EVOQ, 20/70 for PerkinElmer QSight: the nitrogen-to-air ratio each manufacturer specifies, without oversizing.
The grade LC-MS calls for
99 % nitrogen at a –45 °C dew point, filtered to 0.01 µm — exactly what nebuliser, desolvation and curtain gas need, every day.
Each gas at its own pressure
On DUO and TRIO, every line is regulated independently from 0.5 to 8 bar directly on the touchscreen.
Nothing to replace inside
No compressor, no membrane, no cartridge: the carbon molecular sieve regenerates at every cycle. Internally maintenance-free.
Certified for every market
CE, UL and CSA marked, so the same generator installs in Europe, the Americas and beyond.
Connected
7″ touchscreen and Ethernet on every model; TRIO adds RS485, USB logbook download and a power-economy mode.
The family
Three platforms, five models
99 % N₂, –45 °C
Nitrogen-only LC-MS
40.5 × 32.5 × 69 cm, stackable · ≤ 750 W
N₂ + zero airDUO LCMS-30/3030 + 30 NL/minN₂ 99 % · ZA –50 °C
Shimadzu LCMS-8045 to 9030
48 × 70 × 69 cm · 350 W
N₂ + zero airDUO LCMS-35/5035 + 50 NL/minN₂ 99 % · ZA –50 °C
Bruker EVOQ
48 × 70 × 69 cm · 450 W
N₂ + zero airDUO LCMS-20/7020 + 70 NL/minN₂ 99 % · ZA –50 °C
PerkinElmer QSight
48 × 70 × 69 cm · 500 W
N₂ + zero air + dry airTRIO LCMS-25/20/2520 + 25 + 25 NL/minCurtain N₂ > 99.999 % · ZA < 0.1 ppm HC
SCIEX API 3200 to QTRAP 5500
48 × 70 × 69 cm · 500 W
No compressed air in your laboratory?
We take care of the air too
Every Leman LC-MS generator runs on oil-free, dried compressed air. If your building or laboratory has no air network, we size the supply for you and our local partner delivers it ready to connect.
| Generator | Air needed at full flow |
|---|---|
| SOLO LCMS-20 · 35 · 60 | up to 60 · 105 · 180 NL/min |
| DUO LCMS-30/30 | up to 180 NL/min |
| DUO LCMS-35/50 | up to 255 NL/min |
| DUO LCMS-20/70 | up to 270 NL/min |
| TRIO LCMS-25/20/25 | about 150 NL/min |
Oil-free, dried air to DIN ISO 8573-1 class 3, at least 2 bar above the generator outlet pressure (typically 8 – 10 bar), maximum 12 bar. Flows at 1013 hPa / 20 °C.
Installation
All it needs: compressed air and a socket
Oil-free, dried compressed air (DIN ISO 8573-1 class 3), at least 2 bar above the outlet pressure and up to 12 bar. A DUO draws at most three litres of air for each litre of gas it delivers. Compare the cost with cylinders and dewars in two minutes:
Calculate my savingsNot sure which one fits?
Send us the make and model of your LC-MS, and tell us whether your laboratory has compressed air: we propose the generator and, if needed, the complete air supply.
☎+41 78 228 92 13 ✉sales@leman-instruments.com Send my request