Search

Gas generator line · LC-MS

LC-MS gas generators

Nitrogen and zero air for SCIEX, Shimadzu, Bruker, PerkinElmer, Thermo Fisher, Agilent and Waters — from 20 to 90 L/min.

SOLO, DUO and TRIO make, next to your mass spectrometer, exactly the gases it draws — from the compressed air of your laboratory. No cylinders, no dewars, nothing to replace inside.

SOLO LCMS nitrogen generatorNitrogen

SOLO LCMS

20 · 35 · 60 NL/min

For nitrogen-only LC-MS: Thermo Fisher, Agilent, Waters, Shimadzu LCMS-2050

DUO LCMS nitrogen + zero air generatorNitrogen + zero air

DUO LCMS

30/30 · 35/50 · 20/70 NL/min

One version per brand: Shimadzu, Bruker EVOQ, PerkinElmer QSight

TRIO LCMS nitrogen + zero air + dry air generatorNitrogen + zero air + dry air

TRIO LCMS

20 + 25 + 25 NL/min

The three-gas station for SCIEX, API 3200 to QTRAP 5500

The LC-MS family · nitrogen and zero air

Gas matched to your exact LC-MS — not to a catalogue

LC-MS is the thirstiest instrument in the laboratory: 20 to 90 L/min of nitrogen and zero air, day and night. Each manufacturer asks for a different combination of gases, flows and pressures — so we built one generator for each of them.

SOLO for nitrogen-only platforms, DUO for the dual-gas systems of Shimadzu, Bruker and PerkinElmer, TRIO for the three-gas design of SCIEX. Each one delivers exactly what your instrument draws, from the compressed air you already have.

★

No compressor and no consumables inside. PSA over carbon molecular sieve: nothing to replace in the generator, the same purity and pressure every day.

Find the generator for your instrument

Thermo FisherTSQ seriesSOLO LCMS
Agilent6400 seriesSOLO LCMS
WatersXevo TQ seriesSOLO LCMS
ShimadzuLCMS-2050SOLO LCMS
ShimadzuLCMS-8045 · 8050 · 8060 · 9030DUO LCMS-30/30
BrukerEVOQDUO LCMS-35/50
PerkinElmerQSight (single or dual source)DUO LCMS-20/70
SCIEXAPI 3200 to QTRAP 5500TRIO LCMS
SCIEXNitrogen-only configurationsSOLO LCMS
20 – 90L/min of nitrogen and zero air drawn by a busy LC-MS
5models matched to six instrument brands
< 12 monthstypical return on investment against cylinders and dewars
0compressor and consumables inside the generator
Cylinders and liquid-nitrogen dewarsLeman LC-MS generator
SupplyAbout one B50 cylinder every working day for a single busy instrumentContinuous, from your compressed-air network
ConsistencyPurity and pressure vary from cylinder to cylinderThe same purity and pressure every day
GasesOne cylinder bank per gas, one regulator per lineTwo or three gases from one unit, each at its own pressure
LossesDewars evaporate even at night and over weekendsGas made only as the instrument draws it
HandlingHeavy cylinders, cryogenic liquid, changeovers mid-sequenceNone — runs 24/7 next to the instrument

Why a Leman LC-MS generator

Built around the instrument, not the other way round

◎

Sized to each brand

30/30 for Shimadzu, 35/50 for Bruker EVOQ, 20/70 for PerkinElmer QSight: the nitrogen-to-air ratio each manufacturer specifies, without oversizing.

≡

The grade LC-MS calls for

99 % nitrogen at a –45 °C dew point, filtered to 0.01 µm — exactly what nebuliser, desolvation and curtain gas need, every day.

⇉

Each gas at its own pressure

On DUO and TRIO, every line is regulated independently from 0.5 to 8 bar directly on the touchscreen.

⟳

Nothing to replace inside

No compressor, no membrane, no cartridge: the carbon molecular sieve regenerates at every cycle. Internally maintenance-free.

✓

Certified for every market

CE, UL and CSA marked, so the same generator installs in Europe, the Americas and beyond.

⌘

Connected

7″ touchscreen and Ethernet on every model; TRIO adds RS485, USB logbook download and a power-economy mode.

The family

Three platforms, five models

No compressed air in your laboratory?

We take care of the air too

Every Leman LC-MS generator runs on oil-free, dried compressed air. If your building or laboratory has no air network, we size the supply for you and our local partner delivers it ready to connect.

1We size the air. From your LC-MS and generator, we calculate the flow, pressure and quality the compressed air must have.
2Our local partner supplies it. An oil-free compressor with dryer, filters and receiver, matched to that calculation.
3Delivered ready to connect. One line from the air package to the generator — the LC-MS is running on site-made gas from day one.
GeneratorAir needed at full flow
SOLO LCMS-20 · 35 · 60up to 60 · 105 · 180 NL/min
DUO LCMS-30/30up to 180 NL/min
DUO LCMS-35/50up to 255 NL/min
DUO LCMS-20/70up to 270 NL/min
TRIO LCMS-25/20/25about 150 NL/min

Oil-free, dried air to DIN ISO 8573-1 class 3, at least 2 bar above the generator outlet pressure (typically 8 – 10 bar), maximum 12 bar. Flows at 1013 hPa / 20 °C.

Installation

All it needs: compressed air and a socket

Oil-free, dried compressed air (DIN ISO 8573-1 class 3), at least 2 bar above the outlet pressure and up to 12 bar. A DUO draws at most three litres of air for each litre of gas it delivers. Compare the cost with cylinders and dewars in two minutes:

Calculate my savings

Not sure which one fits?

Send us the make and model of your LC-MS, and tell us whether your laboratory has compressed air: we propose the generator and, if needed, the complete air supply.

☎+41 78 228 92 13 ✉sales@leman-instruments.com Send my request