Emissions & air quality. Zero gas, every 24 hours.

Continuous emission monitors and air-quality stations need a zero-and-span check at least once a day, often at remote shelters nobody visits for weeks. Leman 19" rack and wall generators make that gas on site.

5applications
2Leman product lines
60instruments listed

What this industry needs

A CEMS or AQMS analyser runs continuously, often unattended, under rules that demand a daily zero and span check — 40 CFR Part 60 in the United States, EN 14181 in Europe.

A late cylinder here is not an inconvenience: it is a gap in the compliance record.

FID
H2N2Air
24 hthe zero and span check every CEMS channel must pass
3Ua 19" FIDSTATION50 RC delivers hydrogen and zero air for a THC analyser
87 mmdeep SLIM wall box where a shelter has no rack space left

How it works

From the sample or the process to the result, and the gas used at each step.

Sample is extracted

Flue gas is drawn from the stack, filtered and conditioned, or diluted with clean air at the probe.

Air
Analysers measure

FID for total hydrocarbons, NDIR, chemiluminescence and paramagnetic O₂ run continuously.

H2Air
Zero and span

Every channel is checked against zero gas at least once a day; drift beyond limits invalidates data.

N2Air
Data is reported

Validated readings go to the authority; a missed calibration becomes a gap in the record.

In depth

01Air

The daily calibration drift check

Emission rules on both sides of the Atlantic require a zero and span check on every channel of a continuous monitor, usually every 24 hours. Zero gas must be free of the species measured. A 19" AERO50 RC delivers that zero air from the shelter's own compressed air, so the check never waits for a delivery.

02H2

FID in a shelter

Total-hydrocarbon analysers burn the sample in a hydrogen flame fed with hydrocarbon-free air. FIDSTATION50 RC puts both gases in one 3U chassis next to the analyser, with remote access over Ethernet, so a station can be checked from the office instead of after a two-hour drive.

On the bench

Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.

ApplicationEquipmentGas it needsLeman generator
FID total hydrocarbons (THC)Heated FID analysers in CEMS cabinetsH₂ fuel and zero air, continuousFIDSTATION50 RCAERO50 RCHYDRO50 R
NDIR, chemiluminescence, UV fluorescenceMulti-component extractive analysersZero air for daily zero / spanAERO50 RC
Paramagnetic and zirconia O₂Oxygen analysersNitrogen zero gasNITRO50 RC
Extractive dilution probesAny extractive CEMS sampling systemZero air for dilution and instrument airAERO50 RC
Unmanned shelters, stack-testing skidsAmbient AQMS stationsZero gas without a rackWHC

Instruments we know

From our compatibility lists: each family with its gases and the Leman generators that run it.

FID

THC and online VOC analysers

H2N2Air

Leman generatorsFIDSTATION50 RC · HYDRO50 R

35 instruments in our compatibility lists

Gas analysers and flue gas

N2Air

Leman generatorsNITRO50 L · AERO50 L · NANO COMP

17 instruments in our compatibility lists
680°C

Online TOC for water discharge

Air

Leman generatorsAERO TOC L · NANO COMP

8 instruments in our compatibility lists

Questions we hear

Straight answers to what labs ask us first.

Our CEMS vendor already recommends a gas supply.

The 19" Rack Series and SLIM do not replace your CEMS: they are a gas source that drops into the existing rack or wall. Your relationship with the analyser maker stays the same.

Can we check the generators remotely?

Yes: the rack generators have Ethernet and VNC remote access, so the station can be checked without a site visit.

Your instrument is not listed?Send us the maker, model and detectors: we tell you which generator fits.Ask our engineers

Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.