Emissions & air quality. Zero gas, every 24 hours.
Continuous emission monitors and air-quality stations need a zero-and-span check at least once a day, often at remote shelters nobody visits for weeks. Leman 19" rack and wall generators make that gas on site.
19" RACK SERIESWhat this industry needs
A CEMS or AQMS analyser runs continuously, often unattended, under rules that demand a daily zero and span check — 40 CFR Part 60 in the United States, EN 14181 in Europe.
A late cylinder here is not an inconvenience: it is a gap in the compliance record.
How it works
From the sample or the process to the result, and the gas used at each step.
Flue gas is drawn from the stack, filtered and conditioned, or diluted with clean air at the probe.
FID for total hydrocarbons, NDIR, chemiluminescence and paramagnetic O₂ run continuously.
Every channel is checked against zero gas at least once a day; drift beyond limits invalidates data.
Validated readings go to the authority; a missed calibration becomes a gap in the record.
Where Leman fits
The Leman product lines this industry uses, and what each one does.
Lead product line19" RACK SERIESH₂, N₂ and zero air in a 19" rackH2N2AirAERO50 RC, HYDRO50 R and NITRO50 RC as rack generators, or FIDSTATION50 RC as one dual-gas chassis, built into the same 19" cabinet as the analysers, with remote VNC access over Ethernet.
SLIM45 mm wall and OEM generatorsN2AirWHC THC-free zero gas from a wall box, for a shelter with no rack space or a semi-permanent deployment.
In depth
The daily calibration drift check
Emission rules on both sides of the Atlantic require a zero and span check on every channel of a continuous monitor, usually every 24 hours. Zero gas must be free of the species measured. A 19" AERO50 RC delivers that zero air from the shelter's own compressed air, so the check never waits for a delivery.
FID in a shelter
Total-hydrocarbon analysers burn the sample in a hydrogen flame fed with hydrocarbon-free air. FIDSTATION50 RC puts both gases in one 3U chassis next to the analyser, with remote access over Ethernet, so a station can be checked from the office instead of after a two-hour drive.
On the bench
Application by application: the equipment you will find, the gas it needs and the Leman generator that makes it.
| Application | Equipment | Gas it needs | Leman generator |
|---|---|---|---|
| FID total hydrocarbons (THC) | Heated FID analysers in CEMS cabinets | H₂ fuel and zero air, continuous | FIDSTATION50 RCAERO50 RCHYDRO50 R |
| NDIR, chemiluminescence, UV fluorescence | Multi-component extractive analysers | Zero air for daily zero / span | AERO50 RC |
| Paramagnetic and zirconia O₂ | Oxygen analysers | Nitrogen zero gas | NITRO50 RC |
| Extractive dilution probes | Any extractive CEMS sampling system | Zero air for dilution and instrument air | AERO50 RC |
| Unmanned shelters, stack-testing skids | Ambient AQMS stations | Zero gas without a rack | WHC |
Instruments we know
From our compatibility lists: each family with its gases and the Leman generators that run it.
THC and online VOC analysers
Leman generatorsFIDSTATION50 RC · HYDRO50 R
35 instruments in our compatibility listsGas analysers and flue gas
Online TOC for water discharge
Leman generatorsAERO TOC L · NANO COMP
8 instruments in our compatibility listsQuestions we hear
Straight answers to what labs ask us first.
Our CEMS vendor already recommends a gas supply.
The 19" Rack Series and SLIM do not replace your CEMS: they are a gas source that drops into the existing rack or wall. Your relationship with the analyser maker stays the same.
Can we check the generators remotely?
Yes: the rack generators have Ethernet and VNC remote access, so the station can be checked without a site visit.
Other industries
Your methods and procedures set the gas specifications; a Leman engineer confirms flows, pressures and purities before quotation.