Search

Gas generator line · 19″ rack · CEM & AQMS

19″ rack gas generators

Hydrogen, nitrogen and zero air in a 3U rack — for monitoring shelters that run 24/7/365.

In a CEM or AQMS shelter, a cylinder changeover is a live risk to the monitoring record. Leman rack generators slide into the same 19″ cabinet as your analysers and make the gas on site, on demand — with their own compressor and full remote access.

FIDSTATION50 RC rack hydrogen and zero air generatorHydrogen + zero air

FIDSTATION50 RC

H₂ 250 Nml/min · ZA 2.5 L/min

The all-in-one for FID analysers: fuel and zero air from one 3U instrument.

HYDRO50 R rack hydrogen generatorHydrogen

HYDRO50 R

100 or 250 Nml/min

> 99.9995 % hydrogen from deionised water, 0.5 – 10 bar.

NITRO50 RC rack nitrogen generatorNitrogen

NITRO50 RC

250 Nml/min

> 99.9995 % nitrogen, –50 °C dew point, oil-free compressor inside.

AERO50 RC rack zero air generatorZero air

AERO50 RC

2.5 L/min

< 0.5 ppm HC, CO and CH₄ by hot catalysis, compressor on board.

3U19″ chassis, 55 × 41.5 × 12 cm, in your analyser rack
0cylinders and no compressed-air line — compressor on board
VNCfull remote access to the touchscreen over Ethernet
24/7continuous supply for monitoring that never stops
Cylinders in the shelterLeman rack generators
Monitoring recordChangeovers and empty cylinders interrupt the measurementGas made continuously, 24/7/365
Site visitsDeliveries and swaps at remote stationsWatched and adjusted remotely over VNC
SpaceCylinders, regulators and racks outside the cabinet3U in the same 19″ rack as the analysers
Compressed airNeeded for zero air or nitrogen generatorsOil-free compressor built into each model
SafetyStored high-pressure hydrogen in the shelterHydrogen made on demand, nothing stored

One instrument or one per gas

Two ways to equip the rack

◎

All-in-one: FIDSTATION50 RC

For FID-based analysers (THC, VOC): hydrogen fuel and zero air from a single 3U instrument — one unit to install, one screen to watch.

≡

One generator per gas

HYDRO50 R, NITRO50 RC and AERO50 RC: pick only the gases your station needs, each in its own 3U chassis, each serviced on its own.

Common to every rack model

Built for unattended stations

3U 19″ format · 7″ touchscreen · Ethernet 10/100 with full VNC remote access · automatic switching 90 – 260 VAC · CE marked · return on investment typically within 13 to 15 months.

Calculate my savings

Equip your station

Tell us your analysers and the gases they use: we propose the rack generators that fit your cabinet.

☎+41 78 228 92 13 ✉sales@leman-instruments.com Send my request